Discharge flow rate¹
5000 Ipm | 300 m³ per hour | 10600
scfh | 10.5 STPD | 9540 kg per day
O2 purity @ discharge flow rate
93% +/- 3%
O2 output pressure
6 – 10 psig | 0.4 – 0.7 barg2
Operating temperature
0°F to 120°F | -18°C – 49°C
Power requirements
Site power source
Plant
380/460/575 VAC +/- 10%,50/60/60 Hz +/- 3%, 3-Phase,
1000/800/600 Ampere
380/460/575 VAC , 50/60/60 Hz, 3-Phase, 758/626/501 FLA
Average power consumption
135 – 140 kW at 7 psig (0.5 barg) output pressure
157 – 165 kW at 55 psig (3.8 barg) output pressure (with external booster)
162 – 170 kW at 100 psig (6.9 barg) output pressure (with external booster)
Process outlet connection
6” ANSI 150# Flange (Booster: 2.5”
Internal NPT Fitting)
Unit footprint dimensions (nom.)
Crated dimensions (nom.)
456” L x 190” W x 215” H | 1158 cm L x 483 cm W x 546 cm H
Please contact your PCI representative for shipping information
Unit weight (nom.)
Crated Weight (nom.)
62,250 lbs | 28260 kg
Please contact your PCI representative for shipping information.
Average scheduled
maintenance cost
$200 – $300 per month
Average operating cost
@ 55 psig
$0.10 – $0.14 per 100 scf | $0.03 – $0.05 per m³
Additional available options
Remote monitoring & diagnostics suite
4-20 mA Communication to external controller (0-10V standard)
Mass flow control assembly
Automatic sleep mode feature for low-demand situations
Platinum 3 plus 10 Warranty