Oxygen & nitrogen generation systems · ISO 9001 & ISO 13485 registered

PCI Gases Search
Menu

Home » Oxygen Solutions » Medical Oxygen Industries » Disaster Preparedness

Oxygen Technology Markets

Oxygen Generators for Disaster Relief and Field Hospitals

Medic giving oxygen to a patient in a field hospital

Disaster preparedness

Deployable oxygen generators for disaster relief

The DOCS is the proven commodity in disaster relief applications.

PCI is a leading supplier of the US Military for oxygen generators and storage systems for their Mobile Field Hospitals (MFH) and Casualty evacuation missions. Over their years of deployment PCI’s solutions have saved many lives.

PCI’s DOCS systems can be used in any medical application, from supplying oxygen directly to the hospital’s house supply line to filling cylinders for emergencies and remote applications.

Healthcare professionals across the medical industry rely upon PCI’s VSA technology to reliably deliver medical grade oxygen to their patients.

Compare field hospital oxygen generator models
Emergency medical responder in a high-visibility jacket beside an ambulance at night

80 – 500 lpm

MDOCS oxygen flow range at 93% purity

93% ± 3%

Medical grade oxygen (USP / Ph. Eur.)

~50% less energy

Than a PSA of equivalent size and delivered pressure

No installation

Self-contained, easy to operate and fully deployable

Why on-site oxygen

On-site oxygen empowers your field hospital to…

Our mission is to enable you to have autonomy in your Oxygen supply.

With full certification from all major pharmacopeia monographs (WHO,USP,EP), PCI’s DOCS systems aim to help you take control of your oxygen supply and empower you to provide the best care possible at all times.

Protect your Patients

Feel Secure in your Oxygen Supply

Improve your Efficiency

Preserve your Environment

Reduce your Operating Costs

Simplify your Logistics Chain

Mobile field hospital

Mobile field hospital oxygen supply solution

PCI’s Deployable Oxygen Concentration Systems (DOCS) are the proven commodity in disaster relief applications and mobile field hospitals (MFH). Our self-contained, easy-to-operate, and fully deployable system does NOT require installation.

The illustration shows a typical oxygen solution for a Mobile Field Hospital.

To produce oxygen, these systems utilize a proprietary Vacuum Swing Adsorption (VSA) process.

Diagram of a typical mobile field hospital oxygen supply: DOCS oxygen generator, main supply, patient delivery with alarm box and oxygen back-up system

Built for the harshest environments

Completely self-contained oxygen concentration system with fully integrated oxygen booster for simultaneous cylinder filling

Utilized by customers in the harshest environments across the world

Storage and distribution solutions that make the complete cylinder supply chain and associated handling chores obsolete

Technicians installing a PCI MDOCS 200 oxygen generating system

How it works

How PCI DOCS field hospital oxygen generators work

Based on existing technology used in its military medical oxygen generators, PCI developed a commercial line of on-site oxygen generators:

The DOCS Advantage

Lowest operating cost in its class

Most reliable technology

Extremely low power consumption

Very few components = low maintenance cost

View all PCI oxygen generator products

Civilian Oxygen Distribution System (CODS)

PCI’s oxygen delivery system designed for MFHs uses a modular approach so that it can be easily tailored and scaled to MFH bed capacities.

Patient Oxygen Distribution Systems (PODS)

A system of flow regulators to mount at patients bedside and multiple hoses with quick disconnect fittings to provide the distribution of the oxygen at a regulated pressure and flow.

Surgical Suite Oxygen Distribution System (SSODS)

Provides oxygen to the surgical suite for operating equipment such as ventilators, respirators and anesthesia machines.

Technology

VSA vs. PSA oxygen generators for field hospitals

The medical industry now accepts the advantages PCI’s Vacuum Swing Adsorption (VSA) technology has over that of conventional Pressure Swing Adsorption (PSA). This is due to VSA’s simple design, energy efficient technology, ease of maintenance, and lowest total cost of ownership.

To produce oxygen from air, PCI uses a proprietary Vacuum Swing Adsorption (VSA) process that maximizes sieve and power efficiencies. Such efficiencies translate into low operating costs for oxygen generation.

A VSA will save approximately 50 percent of the energy consumption over a PSA of equivalent size and delivered pressure. A VSA also eliminates 33 percent of the main components and 70 percent of the process valves, which increases its reliability and significantly reduces its maintenance costs.

Power (kWh/m³)

PSA

1.3 – 1.5

PCI VSA

0.65

Main components

PSA

6

PCI VSA

4

Process valves

PSA

10

PCI VSA

3

12 benefits of PCI DOCS oxygen generators

Factory Tested and Certified

Easy Installation (Hours not Days)

Uses Half the Power of Traditional PSA’s

No Air Compressor and Dryer Required

Oil-Free Design and Integrated Safety Features

Energy Saving Load Following Capabilities

Single Bed VSA Minimizes Process Valves and Manifolds

Remote Monitoring and Diagnostics Capabilities

Modular Design Offering Flexibility

Simple Operation and Easy to Maintain

Minimal Space Requirement

Minimal Civil Construction Work Necessary

All of these features reduce the cost of preventative maintenance and repairs, thereby reducing the operating cost.

Lower your cost of oxygen

Generate your own oxygen on site

Why pay an Industrial Gas company to supply your oxygen requirements when you can generate your own Oxygen? With a PCI Gases DOCS onsite Oxygen Generating System you can save money and…

Eliminate high cost purchased gases

Eliminate long term contracts

Eliminate ongoing price increases

Eliminate rental and handling charges

Eliminate delivery & fuel sur-charges

Quality & compliance

Medical grade oxygen that meets USP and European Pharmacopeia monographs

PCI medical devices generate and deliver Oxygen 93% +/- 3% gas quality in compliance with both the American1 and European2 Pharmacopeia monographs for Oxygen 93. Models can be ordered in US FDA3, China FDA (CFDA), or European4 compliant configurations, which also meet the critical requirements for ISO 7396-1:2016 medical gas pipeline system. All units are built to ISO 9001 and ISO 13485 quality standards.

References / Compliance

1 United States Pharmacopoeia Monograph.

2 93% Oxygen Monograph: European Pharmacopeia, Supplement 7.1.

3 FDA 510(K) Clearance.

4 CE Certified and Labelled in accordance with Council Directive 93/42 EEC Concerning Medical Devices (Class IIB); 2006/42 EC Machinery Directive; 97/23/EEC Pressure Equipment Directive (PED) and 2006/95/EC, Low Voltage Electrical Equipment Directive (LVD).

Typical analysis results

Analyte

Specification limit

Typical DOCS result

Oxygen (vol %)

90.0 – 96.0

95.7

Carbon monoxide (ppmv)

5

<1

Carbon dioxide (ppmv)

300

<25

Oil mist (mg/m³)

0.1

<0.01

Nitric oxide (ppmv)

2

<0.1

Nitrogen oxide (ppmv)

2

<0.1

Sulfur dioxide (ppmv)

1

<0.1

Water (ppmv)

67

<2

Oxygen 93% vs 99%: equal quality patient care

Other studies have looked at overall patient health and care. In Canada, forty-eight hospitals were surveyed regarding their ten-year experience using oxygen concentrators as their primary oxygen supply. There were no reported adverse consequences as a result of the source of oxygen and the authors concluded that oxygen concentrators which meet Canadian standards are “safe, reliable, and cost effective.”2

Many international healthcare organizations recommend oxygen concentrators on an equal basis as cylinders for oxygen supply. WHO regards oxygen concentrators as an “effective means of supplying oxygen.”3 After years of using O293 in the field, the US military has declared O293 acceptable in any clinical application.

Beyond clinical considerations, switching to O293 does not require additional equipment vis-à-vis delivery systems. ISO has issued identical regulations regarding O293 and O299 delivery systems, and both the Canadian Standards Association (CSA) and the US military make no distinction between systems.5 In the previously mentioned study in Canada, all forty-eight hospitals sites used concentrators that provided O293 through existing O299 gas pipelines.

2 Friesen, R.M., Raber, M.B., Reimer, D.H., “Oxygen concentrators: a primary oxygen supply source,” Can J Anesth 1999;46:1189.

3 Department of Vaccines and Biologicals, “The Oxygen Concentrator,” in “WHO/UNICEF Product Information Sheets 2000,” World Health Organization, Geneva, 2000, p. 235.

5 Janny Enterprises, “The Clinical Utilization of 93% Oxygen in Civilian Commercial Markets,” 2005, p. 7.

Models

Field hospital oxygen generator models and flow rates

Oxygen Generator Models

Model

Power supply

Flow

Delivery pressure

O₂ purity

MDOCS 80

208V / 3-Phase / 60Hz or 220V / 3-Phase / 50Hz

80 lpm

20-100 psig

93% +/- 3%

MDOCS 200

460V / 3-Phase / 60Hz or 380V / 3-Phase / 50Hz

200 lpm

20-100 psig

93% +/- 3%

MDOCS 500

460V / 3-Phase / 60Hz or 380V / 3-Phase / 50Hz

500 lpm

20-100 psig

93% +/- 3%

Scroll and Explore →

FAQ

Disaster relief and field hospital oxygen questions

Is 93% oxygen safe for hospital patients?

Oxygen 93% (O293) provides the same quality of patient care as oxygen 99% (O299). Clinical and scientific studies in Great Britain, Canada, and the United States have demonstrated that, regardless of whether the oxygen supply is O293 from oxygen concentrators or O299 from cylinders or liquid storage devices, the standard of clinical care remains the same.

Which pharmacopeia monographs does DOCS oxygen meet?

The oxygen of our DOCS units meets the requirements of the two pertinent monographs in the U.S. American and European Pharmacopeias, USP Oxygen 93 Percent and PH EUR Oxygen (93 PERCENT).

Can PCI supply mobile and stationary hospitals?

PCI offers a complete product line that fits your need, be it in a small rural hospital or a 500+ bed large hospital, whether it needs to be mobile or stationary.

Can the system refill backup cylinders?

With a DOCS system PCI can provide a cylinder filling compressor that can refill all the cylinder banks with surplus oxygen production, typically at night, when the operating rooms are not functioning. With this type of system the hospital can be made essentially independent of the costs and logistical issues of outside supplies.

Can the oxygen generator be monitored remotely?

The oxygen concentrator control system includes the ability to remotely monitor critical system functions. All start/stop/alarm/monitoring can be performed from any computer once access to the internet has been established. This feature also provides the customer or PCI the ability to log-on and monitor system performance or troubleshoot operational issues.

Talk to PCI Gases

Ready to Reshape Your Tomorrow?

12201 Magnolia Avenue, Riverside, California 92503, US · +1 951.479.0860 · ox****@******es.com
PCI Gases is an ISO9001 & ISO13485 registered company

Skip to content